This paper evaluates the indoor temperature and thermal sensation inside the naturally ventilated small-medium size, historical Anadolchioi Mosque, built in Constanta, in 1870, for the Muslim minority living in Constanta. Are considered Friday prayers (Dhuhr). The methodology used for this assessment is related to the outdoor and indoor temperatures measurements, each Friday, in July, between 10 AM and 4 PM, due to the fact that in Constanta, Friday prayers (in July) starts between 1.20 PM and 1.23 PM (depending on the sun position). The measurements will indicate that, although indoor temperature is slightly higher than the outdoor one, the average indoor temperature, for the considered period, is in the recommended thermal comfort temperature range, according to ASHRAE 2010. Also, the measured indoor air temperatures and predicted temperature for comfortable indoors- given by Humphreys formula, have been compared, in order to have an idea if the building is able to provide pleasant indoor temperatures. On the other hand, the methodology is focusing on ASHRAE seven point scale, when assessing the thermal sensation. In this respect, a survey regarding the thermal sensation of the occupants indicated that a low percent (5.55%) felt uncomfortable during the religious services. The majority of occupants (77.77%) felt comfortable and do not need a cooler environment. The results are in concordance with the participants’ age profiles: older persons preferring higher indoor temperatures.

References

  1. A. B. Atmaca and G. Z. Gedik, “Evaluation of mosques in terms of thermal comfort and energy consumption in a temperate- humid climate”, Energy and Building, vol 195, pp 195-204, 2019.
     Google Scholar
  2. G. Sarwar, Islam-Faith and Teachings, 3rd Ed Timişoara, Romania: Vanessa, Asociaţia Studenţilor Musulmani din România, 1998, pp 20-30.
     Google Scholar
  3. A. A. A. Shohan and M. B Gadi, “Evaluation of thermal and energy performance in mosque buildings for current situation (simulation study) in mountainous climate of Abha City”, Sustainability, vol 12, no 10, pp 1-37, 2020.
     Google Scholar
  4. S. Shodiya, M. Ben Oumarou, G. Ngala, A. Muhammed and M. Yusuf, “Thermal comfort in naturally ventilated large space building in Maiduguri, Borno State”, ATBU, Journal of Science, Technology & Education (JOSTE), vol 4, no 1, pp 16-24, 2016.
     Google Scholar
  5. G. Calis, B. Alt and M. Kuru, “Thermal Comfort and Occupant satisfaction of a Mosque in a Hot and Humid Climate”, in The 2015 International Workshop in Civil Engineering, Ed. William J. O’Brien, Simone Ponticelli, Austin, 2015, pp 139-147.
     Google Scholar
  6. F. F. Al-ajmi, A. S. Al-azmi and F. A. Alrashidi, “Indoor environmental quality in air- conditioned mosque buildings in Kuwait”, American Journal of Civil Engineering and Architecture, vol 5, no 4, pp 167-173, 2017.
     Google Scholar
  7. L. Nyhagen, “Mosques as gendered spaces: the complexity of women’s compliance with, and resistance to, dominant gender norms, and the importance of male allies”, Religions, Vol 10, no 5, pp 1-15, 2019.
     Google Scholar
  8. F. F. Al-Ajmi, “Thermal comfort in air-conditioned mosques in the dry desert climate, Building and Environment, vol 45, no 3, pp 704-710, 2010.
     Google Scholar
  9. F. S. Sezer and E. Kaymaz, “The user’s perception of indoor comfort conditions in historical mosques: the case of Bursa, Turkey”, International Journal of Humanities and Social Science, vol 6, no 9, pp 43-45, 2016.
     Google Scholar
  10. S. S. Ibrahim, A. Baharun, M. N. M. Nawi and E. Junaidi, “Assesment of thermal comfort in the mosque of Sarawak, Malaysia”, International Journal of Energy and Environment, vol 5, no 3, pp 327-334, 2014.
     Google Scholar
  11. K. S.M. Bughrara, Z. D. Arsan and G. G. Akkurt, “Effect of intervention strategies on seasonal thermal comfort conditions in a historic mosque in the Mediterranean climate”, in The 3rd International Conference on Energy Efficiency in Historic Buildings (EEHB 2018), ed. Swedish Energy Agency, Uppsala University and the Swedish National Heritage Board., Visby, 2018, pp 363-371.
     Google Scholar
  12. A. Gallardo, M. Palme, A. Lobato-Cordero, R.D. Beltran and G. Gaona, “Evaluating thermal comfort in a naturally conditioned office in a temperate climate zone”, Buildings, vol 6, no 3, pp 1-20, 2016.
     Google Scholar
  13. R.L. Hwang and C.-P. Chen, “Field study on behaviours and adaptation of elderly people and their thermal comfort requirements in residential environments”, Indoor Air, vol 20, no 3, pp 235- 245, 2010.
     Google Scholar